5.0
2022-08-15T06:36:06Z
Templates/Server hardware
Template Server HPE ProLiant DL360 SNMP
Template Server HPE ProLiant DL360 SNMP
https://git.zabbix.com/projects/ZBX/repos/zabbix/browse/templates/server/hp/hp_dl360_snmp?at=refs%2Ftags%2F5.0.18
Template for HPE ProLiant DL360 servers with HP iLO version 4 and later.
MIBs used:
CPQHLTH-MIB
SNMPv2-MIB
CPQNIC-MIB
CPQSINFO-MIB
CPQIDA-MIB
Template tooling version used: 0.38
Templates/Server hardware
Disk arrays
Fans
General
Inventory
Network interfaces
Physical disks
Power supply
Status
Temperature
Virtual disks
-
System contact details
SNMP_AGENT
1.3.6.1.2.1.1.4.0
hp.server.contact[sysContact]
1h
2w
0
CHAR
MIB: SNMPv2-MIB
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
CONTACT
General
DISCARD_UNCHANGED_HEARTBEAT
1d
-
System description
SNMP_AGENT
1.3.6.1.2.1.1.1.0
hp.server.descr[sysDescr]
1h
2w
0
CHAR
MIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.
General
DISCARD_UNCHANGED_HEARTBEAT
1d
-
Hardware model name
SNMP_AGENT
1.3.6.1.4.1.232.2.2.4.2.0
hp.server.hw.model[cpqSiProductName]
1h
7d
0
CHAR
MIB: CPQSINFO-MIB
The machine product name. The name of the machine used in this system.
MODEL
Inventory
DISCARD_UNCHANGED_HEARTBEAT
6h
-
Hardware serial number
SNMP_AGENT
1.3.6.1.4.1.232.2.2.2.1.0
hp.server.hw.serialnumber[cpqSiSysSerialNum]
1h
7d
0
CHAR
MIB: CPQSINFO-MIB
The serial number of the physical system unit. The string will be empty if the system does not report the serial number function.
SERIALNO_A
Inventory
DISCARD_UNCHANGED_HEARTBEAT
6h
{diff()}=1 and {strlen()}>0
Device has been replaced (new serial number received)
INFO
Device serial number has changed. Ack to close
YES
-
System location
SNMP_AGENT
1.3.6.1.2.1.1.6.0
hp.server.location[sysLocation]
1h
2w
0
CHAR
MIB: SNMPv2-MIB
The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
LOCATION
General
DISCARD_UNCHANGED_HEARTBEAT
6h
-
System name
SNMP_AGENT
1.3.6.1.2.1.1.5.0
hp.server.name[sysName]
1h
2w
0
CHAR
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
NAME
General
DISCARD_UNCHANGED_HEARTBEAT
6h
{diff()}=1 and {strlen()}>0
System name has changed (new name: {ITEM.VALUE})
INFO
System name has changed. Ack to close.
YES
-
System object ID
SNMP_AGENT
1.3.6.1.2.1.1.2.0
hp.server.objectid[sysObjectID]
15m
2w
0
CHAR
MIB: SNMPv2-MIB
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
General
DISCARD_UNCHANGED_HEARTBEAT
6h
-
System temperature status
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.1.0
hp.server.sensor.temp.status[cpqHeThermalCondition]
5m
7d
0d
MIB: CPQHLTH-MIB
This value specifies the overall condition of the system's thermal environment.
This value will be one of the following:
other(1) Temperature could not be determined.
ok(2) The temperature sensor is within normal operating range.
degraded(3) The temperature sensor is outside of normal operating range.
failed(4) The temperature sensor detects a condition that could permanently damage the system.
Temperature
CPQSINFO-MIB::status
DISCARD_UNCHANGED_HEARTBEAT
6h
-
Overall system health status
SNMP_AGENT
1.3.6.1.4.1.232.6.1.3.0
hp.server.status[cpqHeMibCondition]
5m
7d
0d
MIB: CPQHLTH-MIB
The overall condition. This object represents the overall status of the server information represented by this MIB.
Status
CPQSINFO-MIB::status
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$HEALTH.STATUS.CRIT}
System status is in critical state
Current state: {ITEM.LASTVALUE1}
HIGH
Please check the device for errors.
{last()}={$HEALTH.STATUS.WARN}
System status is in warning state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check the device for warnings.
System status is in critical state
{Template Server HPE ProLiant DL360 SNMP:hp.server.status[cpqHeMibCondition].last()}={$HEALTH.STATUS.CRIT}
-
Uptime
SNMP_AGENT
1.3.6.1.2.1.1.3.0
hp.server.uptime[sysUpTime]
5m
2w
0d
uptime
MIB: SNMPv2-MIB
The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
Status
MULTIPLIER
0.01
{last()}<10m
{HOST.NAME} has been restarted (uptime < 10m)
INFO
Uptime is less than 10 minutes
YES
-
SNMP traps (fallback)
SNMP_TRAP
snmptrap.fallback
2w
0
LOG
The item is used to collect all SNMP traps unmatched by other snmptrap items
General
hh:mm:sszyyyy/MM/dd
{iregexp(cpqHoMibHealthStatusArrayChangeTrap,#1)}=1
cpqHoMibHealthStatusArrayChangeTrap
WARNING
YES
-
SNMP agent availability
INTERNAL
zabbix[host,snmp,available]
5m
7d
Status
zabbix.host.available
DISCARD_UNCHANGED_HEARTBEAT
6h
{max({$SNMP.TIMEOUT})}=0
No SNMP data collection
Current state: {ITEM.LASTVALUE1}
WARNING
SNMP is not available for polling. Please check device connectivity and SNMP settings.
Array controller cache discovery
SNMP_AGENT
discovery[{#CACHE_STATUS},1.3.6.1.4.1.232.3.2.2.2.1.2,{#CACHE_CNTRL_INDEX},1.3.6.1.4.1.232.3.2.2.2.1.1]
array.cache.discovery
1h
Scanning table of Array controllers: CPQIDA-MIB::cpqDaAccelTable
#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery status
SNMP_AGENT
1.3.6.1.4.1.232.3.2.2.2.1.6.{#SNMPINDEX}
hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}]
5m
7d
0d
MIB: CPQIDA-MIB
Cache Module Board Backup Power Status. This monitors the status of each backup power source on the board.
The backup power source can only recharge when the system has power applied. The type of backup power source used is indicated by cpqDaAccelBackupPowerSource.
The following values are valid:
Other (1) Indicates that the instrument agent does not recognize backup power status. You may need to update your software.
Ok (2) The backup power source is fully charged.
Recharging (3) The array controller has one or more cache module backup power sources that are recharging.
Cache module operations such as Battery/Flash Backed Write Cache, Expansion, Extension and Migration are temporarily suspended until the backup power source is fully charged.
Cache module operations will automatically resume when charging is complete.
Failed (4) The battery pack is below the sufficient voltage level and has not recharged in 36 hours.
Your Cache Module board needs to be serviced.
Degraded (5) The battery is still operating, however, one of the batteries in the pack has failed to recharge properly.
Your Cache Module board should be serviced as soon as possible.
NotPresent (6) A backup power source is not present on the cache module board. Some controllers do not have backup power sources.
Capacitor Failed (7) The flash backed cache module capacitor is below the sufficient voltage level and has not recharged in 10 minutes. Your Cache Module board needs to be serviced.
Disk arrays
CPQIDA-MIB::cpqDaAccelBattery
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"} or {last()}={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}
#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state
Current state: {ITEM.LASTVALUE1}
AVERAGE
Please check the device for faults.
{last()}={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}
#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in warning state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check the device for faults.
#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"} or {Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}
#{#CACHE_CNTRL_INDEX}: Disk array cache controller status
SNMP_AGENT
1.3.6.1.4.1.232.3.2.2.2.1.2.{#SNMPINDEX}
hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}]
5m
7d
0d
MIB: CPQIDA-MIB
Cache Module/Operations Status. This describes the status of the cache module and/or cache operations.
The status can be:
Other (1)
Indicates that the instrument agent does not recognize the status of the cache module.
Invalid (2)
Indicates that a cache module board has not been installed in this system or is present but not configured.
Enabled (3)
Indicates that cache operations are currently configured and enabled for at least one logical drive.
Temporarily Disabled (4)
Indicates that cache operations have been temporarily disabled. (5)
Indicates that cache operations have been permanently disabled.
Cache Module Flash Memory Not Attached (6)
Indicates that the flash memory component of the flash backed cache module is not attached. This status will be set when the flash memory is not attached and the Supercap is attached. This value is only used on flash backed cache modules that support removable flash memory.
Cache Module Degraded Failsafe Speed (7)
Indicates that the cache module board is currently degraded and operating at a failsafe speed.
Cache Module Critical Failure (8)
Indicates that the cache module board has encountered a critical failure. The controller is currently operating in Zero Memory Raid mode.
Read Cache Could Not Be Mapped (9)
Indicates that the read cache memory in a split cache configuration could not be mapped by the operating system and as a result is not available.
Disk arrays
CPQIDA-MIB::cpqDaAccelStatus
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!
Current state: {ITEM.LASTVALUE1}
AVERAGE
Please check the device for faults.
{last()}={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"} or {last()}={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"} or {last()}={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check the device for faults.
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}
{last()}<>{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"} and {last()}<>{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is not in optimal state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check the device for faults.
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"} or {Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"} or {Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}
DISCARD_UNCHANGED_HEARTBEAT
6h
Array controller discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.3.2.2.1.1.1,{#CNTLR_SLOT},1.3.6.1.4.1.232.3.2.2.1.1.5,{#CNTLR_LOCATION},1.3.6.1.4.1.232.3.2.2.1.1.20]
array.discovery
1h
Scanning table of Array controllers: CPQIDA-MIB::cpqDaCntlrTable
{#CNTLR_LOCATION}: Disk array controller model
SNMP_AGENT
1.3.6.1.4.1.232.3.2.2.1.1.2.{#SNMPINDEX}
hp.server.hw.diskarray.model[cpqDaCntlrModel.{#SNMPINDEX}]
5m
7d
0d
MIB: CPQIDA-MIB
Array Controller Model. The type of controller card.
Disk arrays
CPQIDA-MIB::cpqDaCntlrModel
DISCARD_UNCHANGED_HEARTBEAT
6h
{#CNTLR_LOCATION}: Disk array controller status
SNMP_AGENT
1.3.6.1.4.1.232.3.2.2.1.1.6.{#SNMPINDEX}
hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}]
5m
7d
0d
MIB: CPQIDA-MIB
This value represents the overall condition of this controller,
and any associated logical drives, physical drives, and array accelerators.
Disk arrays
CPQSINFO-MIB::status
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$DISK.ARRAY.STATUS.CRIT}
{#CNTLR_LOCATION}: Disk array controller is in critical state
Current state: {ITEM.LASTVALUE1}
HIGH
Please check the device for faults.
{last()}={$DISK.ARRAY.STATUS.WARN}
{#CNTLR_LOCATION}: Disk array controller is in warning state
Current state: {ITEM.LASTVALUE1}
AVERAGE
Please check the device for faults.
{#CNTLR_LOCATION}: Disk array controller is in critical state
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}].last()}={$DISK.ARRAY.STATUS.CRIT}
DISCARD_UNCHANGED_HEARTBEAT
6h
FAN discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.7.1.9]
fan.discovery
1h
CPQHLTH-MIB::cpqHeFltTolFanCondition
Fan {#SNMPINDEX}: Fan status
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.7.1.9.{#SNMPINDEX}
hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}]
5m
7d
0
MIB: CPQHLTH-MIB
The condition of the fan.
This value will be one of the following:
other(1) Fan status detection is not supported by this system or driver.
ok(2) The fan is operating properly.
degraded(2) A redundant fan is not operating properly.
failed(4) A non-redundant fan is not operating properly.
Fans
CPQSINFO-MIB::status
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$FAN.STATUS.CRIT}
Fan {#SNMPINDEX}: Fan is in critical state
Current state: {ITEM.LASTVALUE1}
AVERAGE
Please check the fan unit.
{last()}={$FAN.STATUS.WARN}
Fan {#SNMPINDEX}: Fan is in warning state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check the fan unit.
Fan {#SNMPINDEX}: Fan is in critical state
{Template Server HPE ProLiant DL360 SNMP:hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}].last()}={$FAN.STATUS.CRIT}
DISCARD_UNCHANGED_HEARTBEAT
6h
Fiber-Channel interfaces
SNMP_AGENT
discovery[{#ADAPTER_INDEX},1.3.6.1.4.1.232.16.2.7.1.1.1,{#ADAPTER_WWN},1.3.6.1.4.1.232.16.2.7.1.1.6]
fc.if.discovery
1h
CPQFCA-MIB::cpqFcaHostCntlrIndex+CPQFCA-MIB::cpqFcaHostCntlrWorldWideName
WWN {#ADAPTER_WWN} port {#ADAPTER_INDEX}: Status
SNMP_AGENT
1.3.6.1.4.1.232.16.2.7.1.1.4.{#SNMPINDEX}
hp.server.fc.if.status[cpqFcaHostCntlrStatus.{#SNMPINDEX}]
5m
7d
"Fibre Channel Host Controller Status.
The host controller can be in one of the following states:
Other (1)
The agent is unable to determine the status of the host
controller.
Ok (2)
Indicates that the host controller is in normal operation mode.
Failed (3)
Indicates that the host controller has failed and should be
replaced.
Shutdown (4)
Indicates that the host controller has been shutdown.
LoopDegraded (5)
Indicates that the fibre channel connection is degraded.
LoopFailed (6)
Indicates that the fibre channel connection is failed.
NotConnected (7)
Indicates that the fibre channel port is not connected or the
device to which it is connected is powered down."
Network interfaces
CPQFCA-MIB::cpqFcaHostCntlrStatus
{last()}<>1 and {last()}<>2
WWN {#ADAPTER_WWN} port {#ADAPTER_INDEX}: Adapter has failed state
Current state: {ITEM.LASTVALUE1}
HIGH
DISCARD_UNCHANGED_HEARTBEAT
6h
Network interface discovery
SNMP_AGENT
discovery[{#ADAPTER_INDEX},1.3.6.1.4.1.232.18.2.3.1.1.1,{#ADAPTER_NAME},1.3.6.1.4.1.232.18.2.3.1.1.39]
net.if.discovery
1h
CPQIDA-MIB::cpqNicIfPhysAdapterTable
{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Status
SNMP_AGENT
1.3.6.1.4.1.232.18.2.3.1.1.14.{#SNMPINDEX}
hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}]
5m
7d
MIB: CPQNIC-MIB
The physical adapter status. The following values are valid:
unknown(1)
The instrument agent was not able to determine the status of the adapter. The instrument agent may need to be upgraded.
ok(2)
The physical adapter is operating properly.
generalFailure(3)
The physical adapter has failed.
linkFailure(4)
The physical adapter has lost link. Check the cable connections to this adapter.
Network interfaces
CPQNIC-MIB::cpqNicIfPhysAdapterStatus
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}=3
{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed
Current state: {ITEM.LASTVALUE1}
HIGH
Please check the physical adapter.
{last()}=4
{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has lost link
Current state: {ITEM.LASTVALUE1}
AVERAGE
Please check the cable connections to this adapter.
{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed
{Template Server HPE ProLiant DL360 SNMP:hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}].last()}=3
DISCARD_UNCHANGED_HEARTBEAT
6h
Physical disk discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.3.2.5.1.1.5,{#DISK_LOCATION},1.3.6.1.4.1.232.3.2.5.1.1.64]
physicaldisk.discovery
1h
Scanning table of physical drive entries CPQIDA-MIB::cpqDaPhyDrvTable.
{#DISK_LOCATION}: Physical disk media type
SNMP_AGENT
1.3.6.1.4.1.232.3.2.5.1.1.69.{#SNMPINDEX}
hp.server.hw.physicaldisk.media_type[cpqDaPhyDrvMediaType.{#SNMPINDEX}]
7d
0d
MIB: CPQIDA-MIB
Drive Array Physical Drive Media Type. The following values are defined:
other(1) The instrument agent is unable to determine the physical drive’s media type.
rotatingPlatters(2) The physical drive media is composed of rotating platters.
solidState(3) The physical drive media is composed of solid state electronics.
Physical disks
CPQIDA-MIB::cpqDaPhyDrvMediaType
DISCARD_UNCHANGED_HEARTBEAT
6h
{#DISK_LOCATION}: Physical disk model name
SNMP_AGENT
1.3.6.1.4.1.232.3.2.5.1.1.3.{#SNMPINDEX}
hp.server.hw.physicaldisk.model[cpqDaPhyDrvModel.{#SNMPINDEX}]
7d
0
CHAR
MIB: CPQIDA-MIB
Physical Drive Model. This is a text description of the physical drive.
The text that appears depends upon who manufactured the drive and the drive type.
If a drive fails, note the model to identify the type of drive necessary for replacement.
If a model number is not present, you may not have properly initialized the drive array to which the physical drive is attached for monitoring.
Physical disks
DISCARD_UNCHANGED_HEARTBEAT
6h
{#DISK_LOCATION}: Physical disk serial number
SNMP_AGENT
1.3.6.1.4.1.232.3.2.5.1.1.51.{#SNMPINDEX}
hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}]
7d
0
CHAR
MIB: CPQIDA-MIB
Physical Drive Serial Number.
This is the serial number assigned to the physical drive.
This value is based upon the serial number as returned by the SCSI inquiry command
but may have been modified due to space limitations. This can be used for identification purposes.
Physical disks
DISCARD_UNCHANGED_HEARTBEAT
6h
{diff()}=1 and {strlen()}>0
{#DISK_LOCATION}: Disk has been replaced (new serial number received)
INFO
Disk serial number has changed. Ack to close
YES
{#DISK_LOCATION}: Disk size
SNMP_AGENT
1.3.6.1.4.1.232.3.2.5.1.1.45.{#SNMPINDEX}
hp.server.hw.physicaldisk.size[cpqDaPhyDrvMediaType.{#SNMPINDEX}]
7d
0d
B
MIB: CPQIDA-MIB
Physical Drive Size in MB.
This is the size of the physical drive in megabytes.
This value is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ
from the advertised size of a drive. This field is only applicable for controllers which support SCSI drives,
and therefore is not supported by the IDA or IDA-2 controllers. The field will contain 0xFFFFFFFF if the drive capacity cannot be calculated
or if the controller does not support SCSI drives.
Physical disks
MULTIPLIER
1048576
DISCARD_UNCHANGED_HEARTBEAT
6h
{#DISK_LOCATION}: Physical disk S.M.A.R.T. status
SNMP_AGENT
1.3.6.1.4.1.232.3.2.5.1.1.57.{#SNMPINDEX}
hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}]
7d
0d
MIB: CPQIDA-MIB
Physical Drive S.M.A.R.T Status. The following values are defined:
other(1) The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive.
ok(2) Indicates the drive is functioning properly.
replaceDrive(3) Indicates that the drive has a S.M.A.R.T predictive failure error and should be replaced.
Physical disks
CPQIDA-MIB::cpqDaPhyDrvSmartStatus
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or {last()}={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}
{#DISK_LOCATION}: Physical disk S.M.A.R.T. failed
Current state: {ITEM.LASTVALUE1}
HIGH
Disk probably requires replacement.
{#DISK_LOCATION}: Physical disk failed
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}].last()}={$DISK.STATUS.FAIL}
{#DISK_LOCATION}: Physical disk status
SNMP_AGENT
1.3.6.1.4.1.232.3.2.5.1.1.6.{#SNMPINDEX}
hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}]
7d
0d
MIB: CPQIDA-MIB
Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status:
other (1) Indicates that the instrument agent does not recognize the drive.
You may need to upgrade your instrument agent and/or driver software.
ok (2) Indicates the drive is functioning properly.
failed (3) Indicates that the drive is no longer operating and should be replaced.
predictiveFailure(4) Indicates that the drive has a predictive failure error and should be replaced.
Physical disks
CPQIDA-MIB::cpqDaPhyDrvStatus
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$DISK.STATUS.FAIL}
{#DISK_LOCATION}: Physical disk failed
Current status: {ITEM.LASTVALUE1}
HIGH
Please check physical disk for warnings or errors.
{last()}={$DISK.STATUS.WARN}
{#DISK_LOCATION}: Physical disk is in warning state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check physical disk for warnings or errors.
{#DISK_LOCATION}: Physical disk failed
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}].last()}={$DISK.STATUS.FAIL}
DISCARD_UNCHANGED_HEARTBEAT
6h
PSU discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.9.3.1.5,{#CHASSIS_NUM},1.3.6.1.4.1.232.6.2.9.3.1.1,{#BAY_NUM},1.3.6.1.4.1.232.6.2.9.3.1.2]
psu.discovery
1h
CPQHLTH-MIB::cpqHeFltTolPowerSupplyStatus
Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply status
SNMP_AGENT
1.3.6.1.4.1.232.6.2.9.3.1.4.{#SNMPINDEX}
hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}]
5m
7d
0
MIB: CPQHLTH-MIB
The condition of the power supply. This value will be one of the following:
other(1) The status could not be determined or not present.
ok(2) The power supply is operating normally.
degraded(3) A temperature sensor, fan or other power supply component is outside of normal operating range.
failed(4) A power supply component detects a condition that could permanently damage the system.
Power supply
CPQSINFO-MIB::status
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$PSU.STATUS.CRIT}
Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state
Current state: {ITEM.LASTVALUE1}
AVERAGE
Please check the power supply unit for errors.
{last()}={$PSU.STATUS.WARN}
Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in warning state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check the power supply unit for errors.
Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state
{Template Server HPE ProLiant DL360 SNMP:hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}].last()}={$PSU.STATUS.CRIT}
DISCARD_UNCHANGED_HEARTBEAT
6h
Temperature ambient discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]
temp.ambient.discovery
1h
{#SNMPINDEX}
0\.1
B
{#SENSOR_LOCALE}
11
A
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with ambient(11) and 0.1 index filter
Ambient: Temperature sensor condition
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}
hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]
5m
7d
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Temperature
CPQHLTH-MIB::cpqHeTemperatureCondition
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()} = 1
Ambient: Temperature could not be determined
INFO
Temperature could not be determined.
YES
{last()} = 4
Ambient: The temperature sensor detects a condition that could permanently damage the system.
HIGH
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
{last()} = 3
Ambient: The temperature sensor is outside of normal operating range
WARNING
If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Ambient: Temperature
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
hp.server.sensor.temp.value[cpqHeTemperatureCelsius.Ambient.{#SNMPINDEX}]
5m
7d
FLOAT
°C
MIB: CPQHLTH-MIB
Temperature readings of testpoint: Ambient
Temperature
DISCARD_UNCHANGED_HEARTBEAT
6h
DISCARD_UNCHANGED_HEARTBEAT
6h
Temperature CPU discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]
temp.cpu.discovery
1h
{#SENSOR_LOCALE}
6
A
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with cpu(6) filter
CPU-{#SNMPINDEX}: Temperature sensor condition
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}
hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]
5m
7d
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Temperature
CPQHLTH-MIB::cpqHeTemperatureCondition
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()} = 1
CPU-{#SNMPINDEX}: Temperature could not be determined
INFO
Temperature could not be determined.
YES
{last()} = 4
CPU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.
HIGH
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
{last()} = 3
CPU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range
WARNING
If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
CPU-{#SNMPINDEX}: Temperature
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
hp.server.sensor.temp.value[cpqHeTemperatureCelsius.CPU.{#SNMPINDEX}]
5m
7d
FLOAT
°C
MIB: CPQHLTH-MIB
Temperature readings of testpoint: CPU-{#SNMPINDEX}
Temperature
DISCARD_UNCHANGED_HEARTBEAT
6h
DISCARD_UNCHANGED_HEARTBEAT
6h
Temperature discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]
temp.discovery
1h
{#SENSOR_LOCALE}
(4|8|9|12|13)
A
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable
{#SNMPINDEX}: Temperature sensor condition
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}
hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]
5m
7d
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Temperature
CPQHLTH-MIB::cpqHeTemperatureCondition
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()} = 1
{#SNMPINDEX}: Temperature could not be determined
INFO
Temperature could not be determined.
YES
{last()} = 4
{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.
HIGH
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
{last()} = 3
{#SNMPINDEX}: The temperature sensor is outside of normal operating range
WARNING
If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
{#SNMPINDEX}: Temperature sensor location
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.3.{#SNMPINDEX}
hp.server.sensor.temp.locale[cpqHeTemperatureLocale.{#SNMPINDEX}]
5m
7d
MIB: CPQHLTH-MIB
This specifies the location of the temperature sensor present in the system.
Temperature
CPQHLTH-MIB::cpqHeTemperatureLocale
DISCARD_UNCHANGED_HEARTBEAT
6h
{#SNMPINDEX}: Temperature
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
hp.server.sensor.temp.value[cpqHeTemperatureCelsius.{#SNMPINDEX}]
5m
7d
FLOAT
°C
MIB: CPQHLTH-MIB
Temperature readings of testpoint: {#SNMPINDEX}
Temperature
DISCARD_UNCHANGED_HEARTBEAT
6h
DISCARD_UNCHANGED_HEARTBEAT
6h
Temperature I/O discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]
temp.io.discovery
1h
{#SENSOR_LOCALE}
5
A
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with ioBoard(5) filter
I/O-{#SNMPINDEX}: Temperature sensor condition
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}
hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]
5m
7d
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Temperature
CPQHLTH-MIB::cpqHeTemperatureCondition
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()} = 1
I/O-{#SNMPINDEX}: Temperature could not be determined
INFO
Temperature could not be determined.
YES
{last()} = 4
I/O-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.
HIGH
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
{last()} = 3
I/O-{#SNMPINDEX}: The temperature sensor is outside of normal operating range
WARNING
If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
I/O-{#SNMPINDEX}: Temperature
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
hp.server.sensor.temp.value[cpqHeTemperatureCelsius."I/O.{#SNMPINDEX}"]
5m
7d
FLOAT
°C
MIB: CPQHLTH-MIB
Temperature readings of testpoint: I/O-{#SNMPINDEX}
Temperature
DISCARD_UNCHANGED_HEARTBEAT
6h
DISCARD_UNCHANGED_HEARTBEAT
6h
Temperature memory discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]
temp.memory.discovery
1h
{#SENSOR_LOCALE}
7
A
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with memory(7) filter
Memory-{#SNMPINDEX}: Temperature sensor condition
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}
hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]
5m
7d
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Temperature
CPQHLTH-MIB::cpqHeTemperatureCondition
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()} = 1
Memory-{#SNMPINDEX}: Temperature could not be determined
INFO
Temperature could not be determined.
YES
{last()} = 4
Memory-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.
HIGH
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
{last()} = 3
Memory-{#SNMPINDEX}: The temperature sensor is outside of normal operating range
WARNING
If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Memory-{#SNMPINDEX}: Temperature
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
hp.server.sensor.temp.value[cpqHeTemperatureCelsius.Memory.{#SNMPINDEX}]
5m
7d
FLOAT
°C
MIB: CPQHLTH-MIB
Temperature readings of testpoint: Memory-{#SNMPINDEX}
Temperature
DISCARD_UNCHANGED_HEARTBEAT
6h
DISCARD_UNCHANGED_HEARTBEAT
6h
Temperature PSU discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]
temp.psu.discovery
1h
{#SENSOR_LOCALE}
10
A
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with powerSupply(10) filter
PSU-{#SNMPINDEX}: Temperature sensor condition
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}
hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]
5m
7d
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Temperature
CPQHLTH-MIB::cpqHeTemperatureCondition
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()} = 1
PSU-{#SNMPINDEX}: Temperature could not be determined
INFO
Temperature could not be determined.
YES
{last()} = 4
PSU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.
HIGH
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
{last()} = 3
PSU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range
WARNING
If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
PSU-{#SNMPINDEX}: Temperature
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
hp.server.sensor.temp.value[cpqHeTemperatureCelsius.PSU.{#SNMPINDEX}]
5m
7d
FLOAT
°C
MIB: CPQHLTH-MIB
Temperature readings of testpoint: PSU-{#SNMPINDEX}
Temperature
DISCARD_UNCHANGED_HEARTBEAT
6h
DISCARD_UNCHANGED_HEARTBEAT
6h
Temperature system discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]
temp.system.discovery
1h
{#SENSOR_LOCALE}
3
A
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with system(3) filter
System-{#SNMPINDEX}: Temperature sensor condition
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}
hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]
5m
7d
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
Temperature
CPQHLTH-MIB::cpqHeTemperatureCondition
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()} = 1
System-{#SNMPINDEX}: Temperature could not be determined
INFO
Temperature could not be determined.
YES
{last()} = 4
System-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.
HIGH
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
{last()} = 3
System-{#SNMPINDEX}: The temperature sensor is outside of normal operating range
WARNING
If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
System-{#SNMPINDEX}: Temperature
SNMP_AGENT
1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
hp.server.sensor.temp.value[cpqHeTemperatureCelsius.System.{#SNMPINDEX}]
5m
7d
FLOAT
°C
MIB: CPQHLTH-MIB
Temperature readings of testpoint: System-{#SNMPINDEX}
Temperature
DISCARD_UNCHANGED_HEARTBEAT
6h
DISCARD_UNCHANGED_HEARTBEAT
6h
Virtual disk discovery
SNMP_AGENT
discovery[{#SNMPVALUE},1.3.6.1.4.1.232.3.2.3.1.1.2,{#DISK_NAME},1.3.6.1.4.1.232.3.2.3.1.1.14]
virtualdisk.discovery
1h
CPQIDA-MIB::cpqDaLogDrvTable
Disk {#SNMPINDEX}({#DISK_NAME}): Layout type
SNMP_AGENT
1.3.6.1.4.1.232.3.2.3.1.1.3.{#SNMPINDEX}
hp.server.hw.virtualdisk.layout[cpqDaLogDrvFaultTol.{#SNMPINDEX}]
5m
7d
Logical Drive Fault Tolerance.
This shows the fault tolerance mode of the logical drive.
Virtual disks
CPQIDA-MIB::cpqDaLogDrvFaultTol
DISCARD_UNCHANGED_HEARTBEAT
6h
Disk {#SNMPINDEX}({#DISK_NAME}): Disk size
SNMP_AGENT
1.3.6.1.4.1.232.3.2.3.1.1.9.{#SNMPINDEX}
hp.server.hw.virtualdisk.size[cpqDaLogDrvSize.{#SNMPINDEX}]
5m
7d
0d
B
Logical Drive Size.
This is the size of the logical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a
megabyte when giving drive capacities so this value may
differ from the advertised size of a drive.
Virtual disks
MULTIPLIER
1048576
DISCARD_UNCHANGED_HEARTBEAT
6h
Disk {#SNMPINDEX}({#DISK_NAME}): Status
SNMP_AGENT
1.3.6.1.4.1.232.3.2.3.1.1.4.{#SNMPINDEX}
hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}]
5m
7d
Logical Drive Status.
Virtual disks
CPQIDA-MIB::cpqDaLogDrvStatus
DISCARD_UNCHANGED_HEARTBEAT
6h
{last()}={$VDISK.STATUS.CRIT}
Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed
Current state: {ITEM.LASTVALUE1}
HIGH
Please check virtual disk for warnings or errors.
{last()}<>{$VDISK.STATUS.OK}
Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk is not in OK state
Current state: {ITEM.LASTVALUE1}
WARNING
Please check virtual disk for warnings or errors.
Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed
{Template Server HPE ProLiant DL360 SNMP:hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}].last()}={$VDISK.STATUS.CRIT}
DISCARD_UNCHANGED_HEARTBEAT
6h
{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}
7
The critical status of the disk array cache battery for trigger expression.
{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"}
4
The critical status of the disk array cache battery for trigger expression.
{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}
5
The warning status of the disk array cache battery for trigger expression.
{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"notPresent"}
6
The warning status of the disk array cache battery for trigger expression.
{$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}
8
The critical status of the disk array cache for trigger expression.
{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"}
3
The normal status of the disk array cache for trigger expression.
{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"}
7
The warning status of the disk array cache for trigger expression.
{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}
6
The warning status of the disk array cache for trigger expression.
{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"}
9
The warning status of the disk array cache for trigger expression.
{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}
2
The warning status of the disk array cache for trigger expression.
{$DISK.ARRAY.STATUS.CRIT}
4
The critical status of the disk array for trigger expression.
{$DISK.ARRAY.STATUS.WARN}
3
The warning status of the disk array for trigger expression.
{$DISK.SMART.STATUS.FAIL:"replaceDrive"}
3
The critical S.M.A.R.T status of the disk for trigger expression.
{$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}
4
The critical S.M.A.R.T status of the disk for trigger expression.
{$DISK.STATUS.FAIL}
3
The critical status of the disk for trigger expression.
{$DISK.STATUS.WARN}
4
The warning status of the disk for trigger expression.
{$FAN.STATUS.CRIT}
4
The critical value of the FAN sensor for trigger expression.
{$FAN.STATUS.WARN}
3
The warning value of the FAN sensor for trigger expression.
{$HEALTH.STATUS.CRIT}
4
The critical status of the health for trigger expression.
{$HEALTH.STATUS.WARN}
3
The warning status of the health for trigger expression.
{$PSU.STATUS.CRIT}
4
The critical value of the PSU sensor for trigger expression.
{$PSU.STATUS.WARN}
3
The warning value of the PSU sensor for trigger expression.
{$SNMP.TIMEOUT}
5m
The time interval for SNMP agent availability trigger expression.
{$VDISK.STATUS.CRIT}
3
The critical status of the virtual disk for trigger expression.
{$VDISK.STATUS.OK}
2
The normal status of the virtual disk for trigger expression.
CPQFCA-MIB::cpqFcaHostCntlrStatus
1
other
2
ok
3
failed
4
shutdown
5
loopDegraded
6
loopFailed
7
notConnected
CPQHLTH-MIB::cpqHeTemperatureCondition
1
other
2
ok
3
degraded
4
failed
CPQHLTH-MIB::cpqHeTemperatureLocale
1
other
2
unknown
3
system
4
systemBoard
5
ioBoard
6
cpu
7
memory
8
storage
9
removableMedia
10
powerSupply
11
ambient
12
chassis
13
bridgeCard
CPQIDA-MIB::cpqDaAccelBattery
1
Other
2
Ok
3
Recharging
4
Failed
5
Degraded
6
Not Present
7
Capacitor failed
CPQIDA-MIB::cpqDaAccelStatus
1
other
2
invalid
3
enabled
4
tmpDisabled
5
permDisabled
6
cacheModFlashMemNotAttached
7
cacheModDegradedFailsafeSpeed
8
cacheModCriticalFailure
9
cacheReadCacheNotMapped
CPQIDA-MIB::cpqDaCntlrModel
1
other
2
ida
3
idaExpansion
4
ida-2
5
smart
6
smart-2e
7
smart-2p
8
smart-2sl
9
smart-3100es
10
smart-3200
11
smart-2dh
12
smart-221
13
sa-4250es
14
sa-4200
15
sa-integrated
16
sa-431
17
sa-5300
18
raidLc2
19
sa-5i
20
sa-532
21
sa-5312
22
sa-641
23
sa-642
24
sa-6400
25
sa-6400em
26
sa-6i
27
sa-generic
29
sa-p600
30
sa-p400
31
sa-e200
32
sa-e200i
33
sa-p400i
34
sa-p800
35
sa-e500
36
sa-p700m
37
sa-p212
38
sa-p410
39
sa-p410i
40
sa-p411
41
sa-b110i
42
sa-p712m
43
sa-p711m
44
sa-p812
45
sw-1210m
46
sa-p220i
47
sa-p222
48
sa-p420
49
sa-p420i
50
sa-p421
51
sa-b320i
52
sa-p822
53
sa-p721m
54
sa-b120i
55
hps-1224
56
hps-1228
57
hps-1228m
58
sa-p822se
59
hps-1224e
60
hps-1228e
61
hps-1228em
62
sa-p230i
63
sa-p430i
64
sa-p430
65
sa-p431
66
sa-p731m
67
sa-p830i
68
sa-p830
69
sa-p831
70
sa-p530
71
sa-p531
72
sa-p244br
73
sa-p246br
74
sa-p440
75
sa-p440ar
76
sa-p441
77
sa-p741m
78
sa-p840
79
sa-p841
80
sh-h240ar
81
sh-h244br
82
sh-h240
83
sh-h241
84
sa-b140i
85
sh-generic
88
sa-p840ar
CPQIDA-MIB::cpqDaLogDrvFaultTol
0
other
2
none
3
RAID-1/RAID-10
4
RAID-4
5
RAID-5
7
RAID-6
8
RAID-50
9
RAID-60
10
RAID-1 ADM
11
RAID-10 ADM
CPQIDA-MIB::cpqDaLogDrvStatus
1
other
2
ok
3
failed
4
unconfigured
5
recovering
6
readyForRebuild
7
rebuilding
8
wrongDrive
9
badConnect
10
overheating
11
shutdown
12
expanding
13
notAvailable
14
queuedForExpansion
15
multipathAccessDegraded
16
erasing
17
predictiveSpareRebuildReady
18
rapidParityInitInProgress
19
rapidParityInitPending
20
noAccessEncryptedNoCntlrKey
21
unencryptedToEncryptedInProgress
22
newLogDrvKeyRekeyInProgress
23
noAccessEncryptedCntlrEncryptnNotEnbld
24
unencryptedToEncryptedNotStarted
25
newLogDrvKeyRekeyRequestReceived
CPQIDA-MIB::cpqDaPhyDrvMediaType
1
Other
2
rotatingPlatters
3
solidState
CPQIDA-MIB::cpqDaPhyDrvSmartStatus
1
other
2
ok
3
replaceDrive
4
replaceDriveSSDWearOut
CPQIDA-MIB::cpqDaPhyDrvStatus
1
other
2
ok
3
failed
4
predictiveFailure
CPQNIC-MIB::cpqNicIfPhysAdapterStatus
1
unknown
2
ok
3
generalFailure
4
linkFailure
CPQSINFO-MIB::status
1
other
2
ok
3
degraded
4
failed
zabbix.host.available
0
not available
1
available
2
unknown