3.4
2015-12-30T14:41:30Z
Templates/Server hardware
Template Server Cisco UCS SNMPv2
Template Server Cisco UCS SNMPv2
Template Server Cisco UCS version: 0.15
Overview: for Cisco UCS via Integrated Management Controller
MIBs used:
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Templates/Server hardware
Disk arrays
Fans
Inventory
Physical disks
Power supply
Status
Temperature
Virtual disks
Temperature Discovery
4
{$SNMP_COMMUNITY}
discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.9.44.1.2]
temp.discovery
1h
0
0
0
0
0
0
30d
{#SENSOR_LOCATION}.Ambient: Temperature
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.9.44.1.4.{#SNMPINDEX}
sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}]
3m
30d
365d
0
0
°C
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Temperature readings of testpoint: {#SENSOR_LOCATION}.Ambient
0
Temperature
{#SENSOR_LOCATION}.Front: Temperature
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.9.44.1.8.{#SNMPINDEX}
sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}]
3m
30d
365d
0
0
°C
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnitMbTempStats:frontTemp managed object property
0
Temperature
{#SENSOR_LOCATION}.Rear: Temperature
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.9.44.1.21.{#SNMPINDEX}
sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}]
3m
30d
365d
0
0
°C
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnitMbTempStats:rearTemp managed object property
0
Temperature
{#SENSOR_LOCATION}.IOH: Temperature
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.9.44.1.13.{#SNMPINDEX}
sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}]
3m
30d
365d
0
0
°C
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnitMbTempStats:ioh1Temp managed object property
0
Temperature
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_WARN:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_WARN:"Ambient"}-3
{#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}
0
0
2
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
0
0
4
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].avg(5m)}<{$TEMP_CRIT_LOW:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].min(5m)}>{$TEMP_CRIT_LOW:"Ambient"}+3
{#SENSOR_LOCATION}.Ambient: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}
0
0
3
Last value: {ITEM.LASTVALUE1}.
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_WARN:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_WARN:"Ambient"}-3
{#SENSOR_LOCATION}.Front: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}
0
0
2
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
0
0
4
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].avg(5m)}<{$TEMP_CRIT_LOW:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].min(5m)}>{$TEMP_CRIT_LOW:"Ambient"}+3
{#SENSOR_LOCATION}.Front: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}
0
0
3
Last value: {ITEM.LASTVALUE1}.
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_WARN:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_WARN:"Ambient"}-3
{#SENSOR_LOCATION}.Rear: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}
0
0
2
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
0
0
4
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].avg(5m)}<{$TEMP_CRIT_LOW:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].min(5m)}>{$TEMP_CRIT_LOW:"Ambient"}+3
{#SENSOR_LOCATION}.Rear: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}
0
0
3
Last value: {ITEM.LASTVALUE1}.
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].avg(5m)}>{$TEMP_WARN:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].max(5m)}<{$TEMP_WARN:"Ambient"}-3
{#SENSOR_LOCATION}.IOH: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}
0
0
2
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"Ambient"}-3
{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}
0
0
4
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].avg(5m)}<{$TEMP_CRIT_LOW:"Ambient"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].min(5m)}>{$TEMP_CRIT_LOW:"Ambient"}+3
{#SENSOR_LOCATION}.IOH: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}
0
0
3
Last value: {ITEM.LASTVALUE1}.
0
0
Temperature CPU Discovery
4
{$SNMP_COMMUNITY}
discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.41.2.1.2]
temp.cpu.discovery
1h
0
0
0
0
0
0
30d
{#SENSOR_LOCATION}: Temperature
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.41.2.1.10.{#SNMPINDEX}
sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}]
3m
30d
365d
0
0
°C
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
Cisco UCS processor:EnvStats:temperature managed object property
0
Temperature
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP_WARN:"CPU"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP_WARN:"CPU"}-3
{#SENSOR_LOCATION}: Temperature is above warning threshold: >{$TEMP_WARN:"CPU"}
0
0
2
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP_CRIT:"CPU"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"CPU"}
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"CPU"}-3
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"CPU"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:"CPU"}-3
{#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP_CRIT:"CPU"}
0
0
4
Last value: {ITEM.LASTVALUE1}.
This trigger uses temperature sensor values as well as temperature sensor status if available
0
0
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].avg(5m)}<{$TEMP_CRIT_LOW:"CPU"}
1
{Template Server Cisco UCS SNMPv2:sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].min(5m)}>{$TEMP_CRIT_LOW:"CPU"}+3
{#SENSOR_LOCATION}: Temperature is too low: <{$TEMP_CRIT_LOW:"CPU"}
0
0
3
Last value: {ITEM.LASTVALUE1}.
0
0
PSU Discovery
4
{$SNMP_COMMUNITY}
discovery[{#PSU_LOCATION},1.3.6.1.4.1.9.9.719.1.15.56.1.2]
psu.discovery
1h
0
0
0
0
0
0
30d
{#PSU_LOCATION}: Power supply status
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.15.56.1.7.{#SNMPINDEX}
sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}]
3m
2w
0d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
Cisco UCS equipment:Psu:operState managed object property
0
Power supply
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability
{Template Server Cisco UCS SNMPv2:sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}].count(#1,{$PSU_CRIT_STATUS:"inoperable"},eq)}=1
0
{#PSU_LOCATION}: Power supply is in critical state
0
0
3
Last value: {ITEM.LASTVALUE1}.
Please check the power supply unit for errors
0
0
{Template Server Cisco UCS SNMPv2:sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}].count(#1,{$PSU_WARN_STATUS:"degraded"},eq)}=1
0
{#PSU_LOCATION}: Power supply is in warning state
0
0
2
Last value: {ITEM.LASTVALUE1}.
Please check the power supply unit for errors
0
0
{#PSU_LOCATION}: Power supply is in critical state
{Template Server Cisco UCS SNMPv2:sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}].count(#1,{$PSU_CRIT_STATUS:"inoperable"},eq)}=1
Unit Discovery
4
{$SNMP_COMMUNITY}
discovery[{#UNIT_LOCATION},1.3.6.1.4.1.9.9.719.1.9.35.1.2]
unit.discovery
1h
0
0
0
0
0
0
30d
{#UNIT_LOCATION}: Overall system health status
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.9.35.1.42.{#SNMPINDEX}
system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}]
30s
2w
0d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnit:operState managed object property
0
Status
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState
{#UNIT_LOCATION}: Hardware model name
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.9.35.1.32.{#SNMPINDEX}
system.hw.model[cucsComputeRackUnitModel.{#SNMPINDEX}]
1h
2w
0d
0
1
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnit:model managed object property
0
Inventory
{#UNIT_LOCATION}: Hardware serial number
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.9.35.1.47.{#SNMPINDEX}
system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]
1h
2w
0d
0
1
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnit:serial managed object property
0
Inventory
{Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"computeFailed"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"configFailure"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"unconfigFailure"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"inoperable"},eq)}=1
0
{#UNIT_LOCATION}: System status is in critical state
0
0
4
Last value: {ITEM.LASTVALUE1}.
Please check the device for errors
0
0
{Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_WARN_STATUS:"testFailed"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_WARN_STATUS:"thermalProblem"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_WARN_STATUS:"powerProblem"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_WARN_STATUS:"voltageProblem"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_WARN_STATUS:"diagnosticsFailed"},eq)}=1
0
{#UNIT_LOCATION}: System status is in warning state
0
0
2
Last value: {ITEM.LASTVALUE1}.
Please check the device for warnings
0
0
{#UNIT_LOCATION}: System status is in critical state
{Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"computeFailed"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"configFailure"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"unconfigFailure"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].count(#1,{$HEALTH_CRIT_STATUS:"inoperable"},eq)}=1
{Template Server Cisco UCS SNMPv2:system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}].diff()}=1 and {Template Server Cisco UCS SNMPv2:system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}].strlen()}>0
2
{#UNIT_LOCATION}: Device has been replaced (new serial number received)
0
0
1
Last value: {ITEM.LASTVALUE1}.
Device serial number has changed. Ack to close
0
1
FAN Discovery
4
{$SNMP_COMMUNITY}
discovery[{#FAN_LOCATION},1.3.6.1.4.1.9.9.719.1.15.12.1.2]
fan.discovery
1h
0
0
0
0
0
0
30d
{#FAN_LOCATION}: Fan status
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.15.12.1.9.{#SNMPINDEX}
sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}]
3m
2w
0d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
Cisco UCS equipment:Fan:operState managed object property
0
Fans
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability
{Template Server Cisco UCS SNMPv2:sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}].count(#1,{$FAN_CRIT_STATUS:"inoperable"},eq)}=1
0
{#FAN_LOCATION}: Fan is in critical state
0
0
3
Last value: {ITEM.LASTVALUE1}.
Please check the fan unit
0
0
{Template Server Cisco UCS SNMPv2:sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}].count(#1,{$FAN_WARN_STATUS:"degraded"},eq)}=1
0
{#FAN_LOCATION}: Fan is in warning state
0
0
2
Last value: {ITEM.LASTVALUE1}.
Please check the fan unit
0
0
{#FAN_LOCATION}: Fan is in critical state
{Template Server Cisco UCS SNMPv2:sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}].count(#1,{$FAN_CRIT_STATUS:"inoperable"},eq)}=1
Physical Disk Discovery
4
{$SNMP_COMMUNITY}
discovery[{#DISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.4.1.2]
physicalDisk.discovery
1h
0
0
0
0
0
0
30d
Scanning table of physical drive entries CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskTable.
{#DISK_LOCATION}: Physical disk status
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.4.1.18.{#SNMPINDEX}
system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}]
3m
30d
0d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:diskState managed object property.
0
Physical disks
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus
{#DISK_LOCATION}: Physical disk model name
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.4.1.12.{#SNMPINDEX}
system.hw.physicaldisk.model[cucsStorageLocalDiskSerial.{#SNMPINDEX}]
1h
2w
0d
0
1
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:serial managed object property. Actually returns part number code
0
Physical disks
{#DISK_LOCATION}: Physical disk media type
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.4.1.7.{#SNMPINDEX}
system.hw.physicaldisk.media_type[cucsStorageLocalDiskModel.{#SNMPINDEX}]
1h
2w
0d
0
1
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:model managed object property. Actually returns 'HDD' or 'SSD'
0
Physical disks
{#DISK_LOCATION}: Disk size
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.4.1.13.{#SNMPINDEX}
system.hw.physicaldisk.size[cucsStorageLocalDiskSize.{#SNMPINDEX}]
1h
2w
0d
0
3
B
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:size managed object property. In MB.
0
Physical disks
1
1048576
{Template Server Cisco UCS SNMPv2:system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}].count(#1,{$DISK_FAIL_STATUS:"failed"},eq)}=1
0
{#DISK_LOCATION}: Physical disk failed
0
0
4
Last value: {ITEM.LASTVALUE1}.
Please check physical disk for warnings or errors
0
0
{Template Server Cisco UCS SNMPv2:system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}].count(#1,{$DISK_CRIT_STATUS:"bad"},eq)}=1 or {Template Server Cisco UCS SNMPv2:system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}].count(#1,{$DISK_CRIT_STATUS:"predictiveFailure"},eq)}=1
0
{#DISK_LOCATION}: Physical disk error
0
0
3
Last value: {ITEM.LASTVALUE1}.
Please check physical disk for warnings or errors
0
0
{#DISK_LOCATION}: Physical disk failed
{Template Server Cisco UCS SNMPv2:system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}].count(#1,{$DISK_FAIL_STATUS:"failed"},eq)}=1
Virtual Disk Discovery
4
{$SNMP_COMMUNITY}
discovery[{#VDISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.8.1.2]
virtualdisk.discovery
1h
0
0
0
0
0
0
30d
CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalLunTable
{#VDISK_LOCATION}: Status
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.8.1.10.{#SNMPINDEX}
system.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}]
3m
2w
365d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalLun:presence managed object property
0
Virtual disks
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence
{#VDISK_LOCATION}: Layout type
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.8.1.14.{#SNMPINDEX}
system.hw.virtualdisk.layout[cucsStorageLocalLunType.{#SNMPINDEX}]
1h
2w
365d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalLun:type managed object property
0
Virtual disks
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType
{#VDISK_LOCATION}: Disk size
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.8.1.13.{#SNMPINDEX}
system.hw.virtualdisk.size[cucsStorageLocalLunSize.{#SNMPINDEX}]
1h
2w
0d
0
3
B
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalLun:size managed object property in MB.
0
Virtual disks
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType
1
1048576
{Template Server Cisco UCS SNMPv2:system.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}].count(#1,{$VDISK_OK_STATUS:"equipped"},ne)}=1
0
{#VDISK_LOCATION}: Virtual disk is not in OK state
0
0
2
Last value: {ITEM.LASTVALUE1}.
Please check virtual disk for warnings or errors
0
0
Array Controller Discovery
4
{$SNMP_COMMUNITY}
discovery[{#DISKARRAY_LOCATION},1.3.6.1.4.1.9.9.719.1.45.1.1.2]
array.discovery
1h
0
0
0
0
0
0
30d
Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.
{#DISKARRAY_LOCATION}: Disk array controller status
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.1.1.6.{#SNMPINDEX}
system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}]
5m
1w
0d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
0
Disk arrays
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability
{#DISKARRAY_LOCATION}: Disk array controller model
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.1.1.5.{#SNMPINDEX}
system.hw.diskarray.model[cucsStorageControllerModel.{#SNMPINDEX}]
1d
30d
0d
0
1
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
0
Disk arrays
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_CRIT_STATUS:"inoperable"},eq)}=1
0
{#DISKARRAY_LOCATION}: Disk array controller is in critical state
0
0
4
Last value: {ITEM.LASTVALUE1}.
Please check the device for faults
0
0
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_WARN_STATUS:"degraded"},eq)}=1
0
{#DISKARRAY_LOCATION}: Disk array controller is in warning state
0
0
3
Last value: {ITEM.LASTVALUE1}.
Please check the device for faults
0
0
{#DISKARRAY_LOCATION}: Disk array controller is in critical state
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_CRIT_STATUS:"inoperable"},eq)}=1
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_OK_STATUS:"operable"},ne)}=1
0
{#DISKARRAY_LOCATION}: Disk array controller is not in optimal state
0
0
2
Last value: {ITEM.LASTVALUE1}.
Please check the device for faults
0
0
{#DISKARRAY_LOCATION}: Disk array controller is in critical state
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_CRIT_STATUS:"inoperable"},eq)}=1
{#DISKARRAY_LOCATION}: Disk array controller is in warning state
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_WARN_STATUS:"degraded"},eq)}=1
Array Controller Cache Discovery
4
{$SNMP_COMMUNITY}
discovery[{#DISKARRAY_CACHE_LOCATION},1.3.6.1.4.1.9.9.719.1.45.11.1.2]
array.cache.discovery
1h
0
0
0
0
0
0
30d
Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.
{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery status
4
{$SNMP_COMMUNITY}
1.3.6.1.4.1.9.9.719.1.45.11.1.9.{#SNMPINDEX}
system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}]
5m
1w
0d
0
3
0
0
0
0
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
0
Disk arrays
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS},eq)}=1
0
{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!
0
0
3
Last value: {ITEM.LASTVALUE1}.
Please check the device for faults
0
0
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS},ne)}=1
0
{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is not in optimal state
0
0
2
Last value: {ITEM.LASTVALUE1}.
Please check the device for faults
0
0
{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!
{Template Server Cisco UCS SNMPv2:system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}].count(#1,{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS},eq)}=1
{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS}
2
{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS}
1
{$DISK_ARRAY_CRIT_STATUS:"inoperable"}
2
{$DISK_ARRAY_OK_STATUS:"operable"}
1
{$DISK_ARRAY_WARN_STATUS:"degraded"}
3
{$DISK_CRIT_STATUS:"bad"}
16
{$DISK_CRIT_STATUS:"predictiveFailure"}
11
{$DISK_FAIL_STATUS:"failed"}
9
{$FAN_CRIT_STATUS:"inoperable"}
2
{$FAN_WARN_STATUS:"degraded"}
3
{$HEALTH_CRIT_STATUS:"computeFailed"}
30
{$HEALTH_CRIT_STATUS:"configFailure"}
33
{$HEALTH_CRIT_STATUS:"inoperable"}
60
{$HEALTH_CRIT_STATUS:"unconfigFailure"}
34
{$HEALTH_WARN_STATUS:"diagnosticsFailed"}
204
{$HEALTH_WARN_STATUS:"powerProblem"}
62
{$HEALTH_WARN_STATUS:"testFailed"}
35
{$HEALTH_WARN_STATUS:"thermalProblem"}
60
{$HEALTH_WARN_STATUS:"voltageProblem"}
62
{$PSU_CRIT_STATUS:"inoperable"}
2
{$PSU_WARN_STATUS:"degraded"}
3
{$TEMP_CRIT:"Ambient"}
35
{$TEMP_CRIT_LOW}
5
{$TEMP_CRIT}
60
{$TEMP_WARN:"Ambient"}
30
{$TEMP_WARN}
50
{$VDISK_OK_STATUS:"equipped"}
10
Template Module Generic SNMPv2
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability
0
unknown
1
operable
2
inoperable
3
degraded
4
poweredOff
5
powerProblem
6
removed
7
voltageProblem
8
thermalProblem
9
performanceProblem
10
accessibilityProblem
11
identityUnestablishable
12
biosPostTimeout
13
disabled
14
malformedFru
15
backplanePortProblem
16
chassisIntrusion
51
fabricConnProblem
52
fabricUnsupportedConn
81
config
82
equipmentProblem
83
decomissioning
84
chassisLimitExceeded
100
notSupported
101
discovery
102
discoveryFailed
103
identify
104
postFailure
105
upgradeProblem
106
peerCommProblem
107
autoUpgrade
108
linkActivateBlocked
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState
0
indeterminate
1
unassociated
10
ok
11
discovery
12
config
13
unconfig
14
powerOff
15
restart
20
maintenance
21
test
29
computeMismatch
30
computeFailed
31
degraded
32
discoveryFailed
33
configFailure
34
unconfigFailed
35
testFailed
36
maintenanceFailed
40
removed
41
disabled
50
inaccessible
60
thermalProblem
61
powerProblem
62
voltageProblem
63
inoperable
101
decomissioning
201
biosRestore
202
cmosReset
203
diagnostics
204
diagnosticsFailed
210
pendingReboot
211
pendingReassociation
212
svnicNotPresent
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus
0
unknown
1
online
2
unconfiguredGood
3
globalHotSpare
4
dedicatedHotSpare
5
jbod
6
offline
7
rebuilding
8
copyback
9
failed
10
unconfiguredBad
11
predictiveFailure
12
disabledForRemoval
13
foreignConfiguration
14
zeroing
15
good
16
bad
17
lockedForeignConfiguration
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType
0
unspecified
1
simple
2
mirror
3
stripe
4
raid
5
stripeParity
6
stripeDualParity
7
mirrorStripe
8
stripeParityStripe
9
stripeDualParityStripe
CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence
0
unknown
1
empty
10
equipped
11
missing
12
mismatch
13
equippedNotPrimary
14
equippedSlave
15
mismatchSlave
16
missingSlave
20
equippedIdentityUnestablishable
21
mismatchIdentityUnestablishable
22
equippedWithMalformedFru
30
inaccessible
40
unauthorized
100
notSupported
101
equippedUnsupported
102
equippedDiscNotStarted
103
equippedDiscInProgress
104
equippedDiscError
105
equippedDiscUnknown