[ZBX-17480] Template Module Cisco CISCO-ENVMON-MIB SNMPv2 - Incorrect trigger context Macros Created: 2020 Mar 19 Updated: 2024 Apr 10 Resolved: 2020 Jun 11 |
|
Status: | Closed |
Project: | ZABBIX BUGS AND ISSUES |
Component/s: | Templates (T) |
Affects Version/s: | 4.4.6, 5.0.0alpha2 |
Fix Version/s: | 4.0.22rc1, 5.0.2rc1, 5.2.0alpha1, 5.2 (plan) |
Type: | Problem report | Priority: | Minor |
Reporter: | Arturs Lontons | Assignee: | Tikhon Uskov (Inactive) |
Resolution: | Fixed | Votes: | 0 |
Labels: | None | ||
Remaining Estimate: | Not Specified | ||
Time Spent: | Not Specified | ||
Original Estimate: | Not Specified |
Team: | |
Sprint: | Sprint 63 (Apr 2020), Sprint 64 (May 2020), Sprint 65 (Jun 2020) |
Story Points: | 1 |
Description |
The out-of-the-box macro Template Module Cisco CISCO-ENVMON-MIB SNMPv2 on version 4.4 and 5.0 alpha (haven't checked others) has misconfigured trigger expressions in the Temperature Discovery LLD trigger prototypes, for example: {Template Module Cisco CISCO-ENVMON-MIB SNMPv2:sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:""} While it should be:
{Template Module Cisco CISCO-ENVMON-MIB SNMPv2:sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:"{#SNMPVALUE}"}
|
Comments |
Comment by Tikhon Uskov (Inactive) [ 2020 Jun 10 ] |
Available in :
|