[ZBX-2071] Zabbix frontend fails on IPMI sensors with trailing spaces Created: 2010 Feb 24  Updated: 2017 May 30  Resolved: 2012 Jan 31

Status: Closed
Project: ZABBIX BUGS AND ISSUES
Component/s: Frontend (F)
Affects Version/s: 1.8.1
Fix Version/s: 2.0.0rc1

Type: Incident report Priority: Major
Reporter: Yuri Vasilevski Assignee: Unassigned
Resolution: Fixed Votes: 0
Labels: ipmi
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Issue Links:
Duplicate
duplicates ZBXNEXT-903 Redesign Configuration->Items Closed

 Description   

Zabbix frontend should not sanitize the input on IPMI sensor field as sensor names can contain trailing spaces.

Here at UNAM we have a cluster with HP ProLiant DL145 G2 computing nodes that support IPMI via iLO, the problem is that among the 22 sensors it has, two of them have names with trailing spaces (i.e. "VBAT " and "VCC5V ") which zabbix is able to monitor only if I manually change the "ipmi_sensor" column from table "items" in my database.

So the problem is that I'm unable to define the items to monitor for this IPMI sensors via GUI, be it manually adding sensor information or exporting to xml -> modifying sensor name in xml file -> importing from xml.

Thanks,
Yuri.



 Comments   
Comment by Eduards Samersovs (Inactive) [ 2012 Jan 25 ]

Resolved in ZBXNEXT-903

Comment by Alexei Vladishev [ 2012 Jan 30 ]

Reopening, should be closed only after proper testing.

Comment by Alexei Vladishev [ 2012 Jan 31 ]

Tested under ZBXNEXT-903, works fine.

Comment by richlv [ 2013 Mar 28 ]

also see ZBX-6445

Generated at Thu Apr 18 03:25:45 EEST 2024 using Jira 9.12.4#9120004-sha1:625303b708afdb767e17cb2838290c41888e9ff0.