[ZBX-25726] 7.2 database version does not match Created: 2024 Dec 11 Updated: 2024 Dec 11 Resolved: 2024 Dec 11 |
|
Status: | Closed |
Project: | ZABBIX BUGS AND ISSUES |
Component/s: | None |
Affects Version/s: | 7.2.0 |
Fix Version/s: | None |
Type: | Problem report | Priority: | Trivial |
Reporter: | Tristis Oris | Assignee: | Zabbix Development Team |
Resolution: | Won't fix | Votes: | 0 |
Labels: | None | ||
Remaining Estimate: | Not Specified | ||
Time Spent: | Not Specified | ||
Original Estimate: | Not Specified | ||
Environment: |
Ubuntu 24 |
Description |
Steps to reproduce:
Result: The Zabbix database version does not match current requirements. Your database version: 7000000. Required version: 7020000. Please contact your system administrator.
run db script, which been moved without notification at changelog. cat /usr/share/zabbix/sql-scripts/postgresql/timescaledb/schema.sql | sudo -u postgres psql zabbix CREATE FUNCTION NOTICE: function base36_decode(pg_catalog.varchar) does not exist, skipping DROP FUNCTION NOTICE: PostgreSQL version 16.6 (Ubuntu 16.6-1.pgdg24.04+1) is valid NOTICE: TimescaleDB extension is detected NOTICE: TimescaleDB version 2.17.2 is valid NOTICE: table "history" is already a hypertable, skipping NOTICE: table "history_uint" is already a hypertable, skipping NOTICE: table "history_log" is already a hypertable, skipping NOTICE: table "history_text" is already a hypertable, skipping NOTICE: table "history_str" is already a hypertable, skipping NOTICE: table "history_bin" is already a hypertable, skipping NOTICE: table "auditlog" is already a hypertable, skipping NOTICE: table "trends" is already a hypertable, skipping NOTICE: table "trends_uint" is already a hypertable, skipping NOTICE: TimescaleDB extension is already installed; not changing configuration NOTICE: TimescaleDB is configured successfully DO ** |
Comments |
Comment by Alexander Vladishev [ 2024 Dec 11 ] |
The database version (7.0) does not match the frontend version (7.2). If you are setting up a new database, you need to use the schema and initial data from the 7.2 distribution. If you are upgrading your existing installation from version 7.0 to 7.2, you need to start the Zabbix server 7.2 so it can update the database. |