[ZBX-3768] gui and server process units "s" differently than stated in documentation Created: 2011 Apr 29  Updated: 2017 May 30  Resolved: 2011 Jun 09

Status: Closed
Project: ZABBIX BUGS AND ISSUES
Component/s: Frontend (F)
Affects Version/s: 1.8.5
Fix Version/s: 1.8.6, 1.9.5 (alpha)

Type: Incident report Priority: Minor
Reporter: Aleksandrs Saveljevs Assignee: Unassigned
Resolution: Fixed Votes: 0
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified


 Description   

Documentation at http://www.zabbix.com/documentation/1.8/manual/web_interface/configuration#items says the following about units "s":

"s - translated to "yyymmmdddhhhmmmsss", parameter is treated as number of seconds. Only 3 upper major units are shown, like 1m3w5d or 2h4m46s. If there are no weeks to display, only two levels are displayed - "1m5d" (no hours, minutes or seconds are shown)."

GUI shows "1500000" seconds as "2w 3d 8h", i.e. it shows spaces between units.

Server shows "1500000" seconds as "17d8h40m0s", i.e. no weeks and more than three upper major units.



 Comments   
Comment by Alexander Vladishev [ 2011 Jun 02 ]

Fixed in the development branch svn://svn.zabbix.com/branches/dev/ZBX-3768

Comment by Alexander Vladishev [ 2011 Jun 09 ]

Fixed in the version pre1.8.6, r20151