[ZBX-7260] Wrong RPC call to JS RPC Created: 2013 Oct 31 Updated: 2017 May 30 Resolved: 2013 Nov 01 |
|
Status: | Closed |
Project: | ZABBIX BUGS AND ISSUES |
Component/s: | Frontend (F) |
Affects Version/s: | 2.1.9 |
Fix Version/s: | 2.1.9, 2.2.0 |
Type: | Incident report | Priority: | Major |
Reporter: | Oleg Egorov (Inactive) | Assignee: | Ivo Kurzemnieks |
Resolution: | Fixed | Votes: | 0 |
Labels: | js | ||
Remaining Estimate: | Not Specified | ||
Time Spent: | Not Specified | ||
Original Estimate: | Not Specified |
Issue Links: |
|
Description |
Created screen Open Monitoring->Screen Change group and time bar period Result: Sometimes problems exist after page refresh in Monitoring->screen page |
Comments |
Comment by Ivo Kurzemnieks [ 2013 Oct 31 ] |
RESOLVED in svn://svn.zabbix.com/branches/dev/ZBX-7260 |
Comment by Pavels Jelisejevs (Inactive) [ 2013 Nov 01 ] |
(1) The same problem exists when acknowledging a trigger in a "Trigger overview" screen element. iivs RESOLVED in r39769 jelisejev Please review my changes in r39773. iivs REOPENED. Undefined variable: page [overview.php:86 → CView->render() → include() in C:\Development\ZBX-7260\frontends\php\include\views\monitoring.overview.php:106] RESOLVED ir r39776 jelisejev CLOSED. |
Comment by Pavels Jelisejevs (Inactive) [ 2013 Nov 01 ] |
TESTED. If (1) is OK you can merge. |
Comment by Pavels Jelisejevs (Inactive) [ 2013 Nov 01 ] |
TESTED. |
Comment by Ivo Kurzemnieks [ 2013 Nov 01 ] |
Fixed in 2.1.9 (trunk) r39788 |