[ZBX-2452] Item with hexadecimal type and integer value don't work if hexadecimal value with space Created: 2010 May 23 Updated: 2021 Aug 16 Resolved: 2010 May 24 |
|
Status: | Closed |
Project: | ZABBIX BUGS AND ISSUES |
Component/s: | Server (S) |
Affects Version/s: | None |
Fix Version/s: | 1.8.3, 1.9.0 (alpha) |
Type: | Incident report | Priority: | Major |
Reporter: | Petrov Vladimir | Assignee: | Unassigned |
Resolution: | Fixed | Votes: | 1 |
Labels: | None | ||
Remaining Estimate: | Not Specified | ||
Time Spent: | Not Specified | ||
Original Estimate: | Not Specified | ||
Environment: |
zabbix 1.8.2, snmp agent for qlogic sanbox 5600 |
Description |
Log of zabbix server write Item [Device:connUnitPortStatCountRxElements.1] error: Type of received value [00 00 00 DF DD 30 74 1C] is not suitable for value type [Numeric (integer 64bit)] Please, apply the patch as http://ramblings.narrabilis.com/wp/qlogic-sanbox-zabbix/ |
Comments |
Comment by Aleksandrs Saveljevs [ 2010 May 24 ] |
Fixed in pre-1.8.3 in r12207. |
Comment by david [ 2021 Aug 16 ] |
you can update your link to http://ramblings.narrabilis.com/index.php/qlogic-sanbox-zabbix |