[ZBX-4810] zabbix Dell_PowerConnect_5224 and Template_Dell_PowerConnect_5324 bug Created: 2012 Mar 28 Updated: 2017 May 30 Resolved: 2012 Apr 28 |
|
Status: | Closed |
Project: | ZABBIX BUGS AND ISSUES |
Component/s: | Templates (T) |
Affects Version/s: | 1.8.10 |
Fix Version/s: | 1.8.13rc1 |
Type: | Incident report | Priority: | Trivial |
Reporter: | pengyao | Assignee: | Unassigned |
Resolution: | Fixed | Votes: | 0 |
Labels: | templates | ||
Remaining Estimate: | Not Specified | ||
Time Spent: | Not Specified | ||
Original Estimate: | Not Specified | ||
Environment: |
DB: mysql |
Description |
Hello, I found a bug about Dell_PowerConnect_5224 and Template_Dell_PowerConnect_5324 Template in ifOutOctets* and ifInOctets*, because the snmp OID return value units is byte, 1Bps = 8 bps, so the Use custom multiplier should be "8", but the default value is "0.125", Please check it. Thanks |
Comments |
Comment by Alexander Vladishev [ 2012 Apr 28 ] |
Thanks! Fixed in version pre-1.8.13rc1 revision 27200. |