    Zabbix v1.8
Incrorrect processing of the "count" function in Zabbix v1.8. 
In case If exists such trigger 
>3 then trigger will be alarmed always, but should be alarmed in case error was 3 time during last minute.
- is duplicated by
- 
                    ZBX-1730 Trigger stopped working after 1.6->1.8 upgrade. -         
- Closed
 
-