Uploaded image for project: 'ZABBIX BUGS AND ISSUES'
  1. ZABBIX BUGS AND ISSUES
  2. ZBX-19521

Change per second preprocessing gives great difference when values received shorter then in one second

    XMLWordPrintable

Details

    • Problem report
    • Status: Open
    • Trivial
    • Resolution: Unresolved
    • None
    • None
    • None
    • None

    Description

      Happens that trapper items receive more values then expected.

      Received values in 100 ms or less after preprocessing gives enormous results.

      It is unable to predict and adjust trigger thresholds for that.

      Formula: (valueprev_value)/(timeprev_time)

      Example for 1 second interval:

      (100-95)/1 = 5

      Example for 100ms interval:

      (100-95)/0.1 = 50

      Example for 10 ms interval:

      (100-95)/0.01 = 500

       

       

      Attachments

        Activity

          People

            zabbix.dev Zabbix Development Team
            atocko Andrey Tocko
            Votes:
            3 Vote for this issue
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated: