Uploaded image for project: 'ZABBIX BUGS AND ISSUES'
  1. ZABBIX BUGS AND ISSUES
  2. ZBX-20895

Incorrect temperature trigger expressions in hardware templates

XMLWordPrintable

    • Icon: Problem report Problem report
    • Resolution: Unresolved
    • Icon: Trivial Trivial
    • None
    • 5.0.22, 6.0.3
    • Templates (T)
    • None
    • Team INT

      Steps to reproduce:
      1. Open hardware template (for example Brocade FC SNMP)
      2. See In Temperature discovery items
      sensor.temp.valueswSensorValue.{#SNMPINDEX}
      sensor.temp.statusswSensorStatus.{#SNMPINDEX}
      with delay 3m

      and trigger with expression like
      avg(<item>,5m)>{$TEMP_CRIT:""}

      Result:
      Triggers calculated average for two items values. Also trigger's expressions calculate every 30 sec, so in some cases only one item value can be present for 5 minute  and triggers can blink.

      Expected:
      Triggers fired when average value for some items values more than threshold.

      Some of affected templates:
      Brocade_Foundry Nonstackable SNMP
      Brocade FC SNMP
      Alcatel Timetra TiMOS SNMP
      Cisco CISCO-ENVMON-MIB SNMP
      Dell Force S-Series SNMP

            zit Zabbix Integration Team
            ychukina Yulia Chukina (Inactive)
            Team INT
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

              Created:
              Updated: