Problem report
-
Resolution: Unresolved
-
Trivial
-
None
-
5.0.22, 6.0.3
-
None
-
Team INT
Steps to reproduce:
1. Open hardware template (for example Brocade FC SNMP)
2. See In Temperature discovery items
sensor.temp.valueswSensorValue.{#SNMPINDEX}
sensor.temp.statusswSensorStatus.{#SNMPINDEX}
with delay 3m
and trigger with expression like
avg(<item>,5m)>{$TEMP_CRIT:""}
Result:
Triggers calculated average for two items values. Also trigger's expressions calculate every 30 sec, so in some cases only one item value can be present for 5 minute and triggers can blink.
Expected:
Triggers fired when average value for some items values more than threshold.
Some of affected templates:
Brocade_Foundry Nonstackable SNMP
Brocade FC SNMP
Alcatel Timetra TiMOS SNMP
Cisco CISCO-ENVMON-MIB SNMP
Dell Force S-Series SNMP