Issue with alert triggers for device restarted

XMLWordPrintable

    • Type: Incident report
    • Resolution: Duplicate
    • Priority: Trivial
    • None
    • Affects Version/s: 5.0.36
    • Component/s: Templates (T)
    • Environment:
      ZABBIX proxies are polling network devices (CISCO IOS, NXOS). We are facing an issue with triggered alert when uptime is reachinf SNMPv2 limit (497 days)

      Steps to reproduce:

      1. Device uptime reach 497 days
      2. Uptime counter restart to 0
      3. Alert "Device has restarted" is triggered 

      Result:
      See screenshot in attchment
      Expected:
      A workaround to not trigger an alert in case uptime counter restart from 0 (after 497 days due to SNMPv2 limitation)

            Assignee:
            Zabbix Support Team
            Reporter:
            Julien JOUANNET
            Team A
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: