Uploaded image for project: 'ZABBIX BUGS AND ISSUES'
  1. ZABBIX BUGS AND ISSUES
  2. ZBX-24351

Bad value in SMART Wear_Leveling_Count for SAMSUNG SSD

XMLWordPrintable

      Hi,

      There is an issue with SMART monitoring for Samsung-based SSD.

      Zabbix Agent 2 gets the RAW value from Smartctl Wear_Leveling_Count but on the SSDs from this brand, the RAW value is not pertinent, the desired value is the normalized one.

      I've seen there is a turnaround for Linux hosts via a host template, but it's of no use for Windows hosts.

      Is it possible to make Samsung SSD Wear_Leveling_Count support accurate by reading the normalized value instead of the raw one ?

      Thanks in advance

      Steps to reproduce:

      • On host: do a smartctl on a Samsung SSD. The Wear_Leveling_Count Normalized and Raw values are what we want to see.
      • On server: do a smart.disk.get, the value passed to Zabbix for the Samsung SSD is the RAW value, not the normalized one.
      • On frontend: the value displayed is actually the raw value: (NB: in order to be able to get csmi0,4 from smartctl, I had to downgrade Agent2 to v. 6.4.8 because of bug ZBX-23789)

       

            zit Zabbix Integration Team
            aquris AXQ
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated: