Cisco Nexus 9000 Series by SNMP uses incorrect MIB for memory monitoring

XMLWordPrintable

    • Sprint candidates
    • 1

      Steps to reproduce:

      1. Template uses OID from CISCO-ENHANCED-MEMPOOL-MIB

      Result:
      Incorrect memory results with:

      • 1.3.6.1.4.1.9.9.221.1.1.1.1.8
      • 1.3.6.1.4.1.9.9.221.1.1.1.1.7

      Expected:
      According to the Cisco TAC team for Nexus devices CISCO-PROCESS-MIB:
      https://www.circitor.fr/Mibs/Html/C/CISCO-PROCESS-MIB.php

      • 1.3.6.1.4.1.9.9.109.1.1.1.1.12 << Memory Used
      • 1.3.6.1.4.1.9.9.109.1.1.1.1.13 << Memory Free
      • 1.3.6.1.4.1.9.9.305.1.1.2 << Memory Percentage

            Assignee:
            Kamil Florowski
            Reporter:
            Edgar Akhmetshin
            Team INT
            Votes:
            1 Vote for this issue
            Watchers:
            10 Start watching this issue

              Created:
              Updated:

                Estimated:
                Original Estimate - Not Specified
                Not Specified
                Remaining:
                Remaining Estimate - Not Specified
                Not Specified
                Logged:
                Time Spent - 20h
                20h