Uploaded image for project: 'ZABBIX BUGS AND ISSUES'
  1. ZABBIX BUGS AND ISSUES
  2. ZBX-25042

{$SNMP.TIMEOUT} ignored by "No SNMP data collection" triggers

XMLWordPrintable

    • Sprint candidates

      Steps to reproduce:

      1. Use any default SNMP template
      2. Set {$SNMP.TIMEOUT} macro to 10m
      3. Wait 10m
      4. SNMP service goes down

      Result:
      "No SNMP data collection" trigger ignores {$SNMP.TIMEOUT} and fires immediately

      Expected:
      "No SNMP data collection" trigger fires after {$SNMP.TIMEOUT}

       

      This issue affects all templates that have Discard unchanged with hearbeat on SNMP agent availability item. I count 36 SNMP templates in 5 template folders like this:

      • net/cisco/cisco_asav_snmp/
      • net/zyxel_snmp/
      • power/apc/
      • server/cisco_ucs_manager_snmp/
      • server/dell/ server/hp/

       

      Generally, doing good triggers with Discard unchanged with heartbeat items is surprisingly hard.