Uploaded image for project: 'ZABBIX BUGS AND ISSUES'
  1. ZABBIX BUGS AND ISSUES
  2. ZBX-25402

Macro functions are not resolved with user macros, if number is used as the last symbol in the macro name

XMLWordPrintable

    • S24-W44/45, S24-W48/49
    • 2

      Steps to reproduce:

      1. Create user macro: {$TEST_1} = 2.56
      2. Add macro with macro function: {{$TEST_1}.fmtnum(2)} in the event name.
      3. Execute actions to switch trigger in a Problem state
      4. See created event details

      Note: issue is not present for places, where macro functions are resolved by frontend

      Result:
      Macro function is not resolved:
      Event name:

      {2.56.fmtnum(2)}

      Expected:
      Macro function should be resolved correctly.