Problem report
-
Resolution: Unresolved
-
Trivial
-
7.0.5
-
None
-
Sprint candidates
Steps to reproduce:
- Create a master template with an item and a trigger.
- Create a linked/child template that is linked to the master template
- Change the severity of the trigger in the linked/child template (override it)
- Update any field (the description for example) of the trigger in the master template
Result:
The overridden severity of the linked/child template is now gone. Back to the same value as the master template trigger.
Expected:
That the severity of the linked/child trigger stays the same.
- caused by
-
ZBXNEXT-8453 Make Trigger and prototype configuration forms modal
- Closed