Problem report
-
Resolution: Unresolved
-
Trivial
-
None
-
7.0.21, 7.4.5, 8.0.0alpha1
Steps to reproduce:
- After HPE updated the firmware, Template template_server_hpe_ilo_http.yaml, It is no longer bringing disc information.
HPE has released a firmware version that fixes this.
Version: 3.15 (13 Aug 2025)
Enhancements
There are no enhancements in the current HPE iLO 5 v3.15 release.
Fixes
Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.
• Fixed an issue where HPE OneView returned inconsistent datatype for network adapter function ID for a server hardware call.
• Fixed an issue where the GPU sensor data and status were missing during nVidia driver load and unload transitions randomly.
• Fixed an issue where during an HPE iLO firmware upgrade to SSP SY 2024.11.02, the RDE VAS went into a freeze state and caused a halt in the upgrade process.
• Fixed an issue where HDDs connected through the SR controller were not consistently displayed in the HPE iLO 5 Firmware Inventory page or via the Redfish API.
https://105.203.203.46/redfish/v1/Systems/1/SmartStorage/ArrayControllers/
{
"@odata.context": "/redfish/v1/$metadata#HpeSmartStorageArrayControllerCollection.HpeSmartStorageArrayControllerCollection",
"@odata.etag": "W/\"AA6D42B0\"",
"@odata.id": "/redfish/v1/Systems/1/SmartStorage/ArrayControllers/",
"@odata.type": "#HpeSmartStorageArrayControllerCollection.HpeSmartStorageArrayControllerCollection",
"Description": "HPE Smart Storage Array Controllers View",
"Name": "HpeSmartStorageArrayControllers",
"Members": [
{ "@odata.id": "/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/" }
],
"[email protected]": 1
}
https://105.203.203.46/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives
{
"@odata.context": "/redfish/v1/$metadata#HpeSmartStorageDiskDriveCollection.HpeSmartStorageDiskDriveCollection",
"@odata.etag": "W/\"E589C4BF\"",
"@odata.id": "/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives",
"@odata.type": "#HpeSmartStorageDiskDriveCollection.HpeSmartStorageDiskDriveCollection",
"Description": "HPE Smart Storage Disk Drives View",
"Name": "HpeSmartStorageDiskDrives",
"Members": [
{ "@odata.id": "/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives/1" }
,
{ "@odata.id": "/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives/2" }
,
{ "@odata.id": "/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives/3" }
],
"[email protected]": 3
}
https://105.203.203.46/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives/1
{
"@odata.context": "/redfish/v1/$metadata#HpeSmartStorageDiskDrive.HpeSmartStorageDiskDrive",
"@odata.etag": "W/\"05E04B73\"",
"@odata.id": "/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives/1",
"@odata.type": "#HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive",
"Id": "1",
"BlockSizeBytes": 512,
"CapacityGB": 600,
"CapacityLogicalBlocks": 1172123568,
"CapacityMiB": 572325,
"CarrierApplicationVersion": "11",
"CarrierAuthenticationStatus": "OK",
"CurrentTemperatureCelsius": 48,
"Description": "HPE Smart Storage Disk Drive View",
"DiskDriveStatusReasons": [
"None"
],
"DiskDriveUse": "Data",
"EncryptedDrive": false,
"FirmwareVersion": {
"Current":
{ "VersionString": "HPD1" }
},
"InterfaceSpeedMbps": 12000,
"InterfaceType": "SAS",
"LegacyBootPriority": "Primary",
"Location": "1I:3:3",
"LocationFormat": "ControllerPort:Box:Bay",
"MaximumTemperatureCelsius": 51,
"MediaType": "HDD",
"Model": "EG000600JWFUR",
"Name": "HpeSmartStorageDiskDrive",
"PowerOnHours": null,
"RotationalSpeedRpm": 10500,
"SSDEnduranceUtilizationPercentage": null,
"SerialNumber": "0BHEAN8H",
"Status":
{ "Health": "OK", "State": "Enabled" }
,
"UncorrectedReadErrors": 0,
"UncorrectedWriteErrors": 0
}
In the Get data item:
Script
Block: var system_storages