ExportXMLWordPrintable

    • Type: Incident report
    • Resolution: Unresolved
    • Priority: Trivial
    • None
    • Affects Version/s: 7.4.14
    • Component/s: None
    • None
    • Environment:
      Dell PowerStore 500T full NVMe SAN with 3 ESXi 8.0.3 PowerEdge R660. Zabbix server 7.4.14 et Zabbix proxy for monitoring ESXi

      Steps to reproduce:

      1. ESXi 8 VMware environment monitored by Zabbix server via VMware Template (VMware, VMware FQDN, VMware Guest, VMware Hypervisor,)
      2. Create a empty VM with NVMe controler and 1 disk
      3. The"Disk device discovery" finds hard drive with item key as "vmware.vm.vfs.dev.read[\{$VMWARE.URL},\{$VMWARE.VM.UUID},ide0:0,bps]" instead nvme0.0
      4. Manually creating item with nvme0.0 is functionnal, only discovery in Vmware Guest is finding item with ide0.0
      5. Creating a empty VM with SCSI controler and disk is discovered correctly with item key "vmware.vm.vfs.dev.read[\{$VMWARE.URL},\{$VMWARE.VM.UUID},scsi0:0,bps]

      Result:

      item key as "vmware.vm.vfs.dev.read[\{$VMWARE.URL},\{$VMWARE.VM.UUID},ide0:0,bps]"

      Expected:
      item key as "vmware.vm.vfs.dev.read[\{$VMWARE.URL},\{$VMWARE.VM.UUID},nvme0:0,bps]"

        1. zabbix.png
          26 kB
          Gérald Debiard

            Assignee:
            Zabbix Support Team
            Reporter:
            Gérald Debiard
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Created:
              Updated: