Uploaded image for project: 'ZABBIX BUGS AND ISSUES'
  1. ZABBIX BUGS AND ISSUES
  2. ZBX-3208

wrong event clock for unknown trigger

XMLWordPrintable

    • Icon: Incident report Incident report
    • Resolution: Fixed
    • Icon: Major Major
    • None
    • 1.8.4rc2
    • Server (S)

      Suppose we have a trapper item of type unsigned integer. Its trigger is in the OK state. We send two values, one shortly after another: -1 and 1. The first one causes a trigger to become UNKNOWN, the other changes the trigger's state back to OK. For some reason, it is possible that the UNKNOWN event has a lower eventid than the OK event, but have a clock higher than the OK event.

            Unassigned Unassigned
            asaveljevs Aleksandrs Saveljevs
            Votes:
            2 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: