Incident report
-
Resolution: Fixed
-
Major
-
1.6
-
None
-
None
-
My server is an Apple xserve dual G4 PPC plaform running yellow dog
linux 3.0. zabbix 1.6 compiled from source with postgresql-7.4.3 and
net-snmp-5.4.2
I only have 1 host configured and that is the cisco pix 515E
7902:20081006:111656 In get_values()
7902:20081006:111656 Query [select i.itemid,i.key_,h.host,h.port,i.delay,i.description,i.nextcheck,i.type,i.snmp_commu
.lastvalue,i.prevvalue,i.hostid,h.status,i.value_type,h.errors_from,i.snmp_port,i.delta,i.prevorgvalue,i.lastclock,i.uni
snmpv3_securitylevel,i.snmpv3_authpassphrase,i.snmpv3_privpassphrase,i.formula,h.available,i.status,i.trapper_hosts,i.lo
,i.params,i.trends,h.useipmi,h.ipmi_port,h.ipmi_authtype,h.ipmi_privilege,h.ipmi_username,h.ipmi_password,i.ipmi_sensor
=1223306221 and i.status in (0,3) and i.type not in (2,7,9,12) and h.status=0 and h.disable_until<=1223306216 and h.erro
roxy_hostid=0 or i.type in (5)) and mod(i.itemid,5)=1 and i.key_ not in ('status','icmpping','icmppingsec','zabbix[log]'
nd 099999999999999 order by i.nextcheck]
7902:20081006:111656 In int_in_list(list:,value:10047)
7902:20081006:111656 End int_in_list(ret:FAIL)
Then it crashes.