Incident report
-
Resolution: Duplicate
-
Major
-
None
-
1.6
-
Zabbix 1.6.3 Ubuntu 8.04, snmp 5.4.1~dfsg-4ubuntu4.2, Funkwerk Rxxx series router latest firmware
After restarting a monitored SNMP device (Funkwerk R1200/R3000 router) via SNMPv3, the monitoring stopped working. The device complained about authentification problems.
A tcpdump showed, that the engineTime differs after the restart, and Zabbix is not syncing again, which produces usmStatsUnknownEngineIDs and usmStatsNotInTimeWindows SNMP messages.
Zabbix stops monitoring until restart of zabbix-server and reactivating the affected items.
Further information can be found in post #17 of http://www.zabbix.com/forum/showthread.php?t=11855&page=2
- duplicates
-
ZBX-2152 multiple SNMPv3 checks get unexpected unpredictable "network error" log messages - all about duplicated "SNMP EngineID"
- Closed