Incident report
-
Resolution: Fixed
-
Major
-
2.3.4
-
None
Feature ZBXNEXT-101 implemented runtime controls to change process log levels. However, when a sleeping process receives a signal, it has a side effect that the process wakes from sleep. So, for instance, a housekeeper, when woken up, will do housekeeping. Simlarly for other processes. They should continue sleeping for the allotted time instead.