Incident report
-
Resolution: Cannot Reproduce
-
Major
-
None
-
1.6
-
None
-
Linux voip.mediatech.local 2.6.18-53.1.4.el5 #1 SMP Fri Nov 30 00:45:16 EST 2007 i686 i686 i386 GNU/Linux
When importing a template, it's multiplier and formula nodes are not taken into account, but the default values are inserted instead.
After importing a template and exporting it, you'll see a difference in the place of these tags.
what i've imported, and what i've got from an export (for only a single item, .gen is generated input, .exp is exported):
- diff -u .gen .exp
-
- .gen 2009-05-11 14:16:44.000000000 +0200
+++ .exp 2009-05-11 14:17:04.000000000 +0200
@@ -6,9 +6,9 @@
<trends>365</trends>
<status>0</status>
<units>A</units>
- .gen 2009-05-11 14:16:44.000000000 +0200
-
- <multiplier>1</multiplier>
+ <multiplier>0</multiplier>
<delta>0</delta> - <formula>0.1</formula>
+ <formula>1</formula>
<lastlogsize>0</lastlogsize>
<logtimefmt></logtimefmt>
<delay_flex></delay_flex>