Template HPE Primera by HTTP trigger for disk failed is wrong.

XMLWordPrintable

    • Type: Change Request
    • Resolution: Duplicate
    • Priority: Major
    • None
    • Affects Version/s: None
    • Component/s: None
    • None
    • Support backlog
    • 0.25

      On template HPE Primera by HTTP, the trigger prototype "Disk {#POSITION}: Failed" inside the Disks discovery will trigger when last(/HPE Primera by HTTP/hpe.primera.disk"{#POSITION}",state)=3. This actually should trigger on state=4

       

      According to Table 76: diskStateEnum enumeration on the API documentation

      https://support.hpe.com/hpesc/public/docDisplay?docId=a00118636en_us&page=GUID-2A083E9D-28CD-47B3-B2F8-CA4BA174FD6D.html

       