Uploaded image for project: 'ZABBIX FEATURE REQUESTS'
  1. ZABBIX FEATURE REQUESTS
  2. ZBXNEXT-9939

Template for Palo Alto Networks PA-1400 Series

XMLWordPrintable

    • Icon: Change Request Change Request
    • Resolution: Unresolved
    • Icon: Medium Medium
    • None
    • None
    • Templates (T)
    • None

      ZBXNEXT-9606 is for PA-440, and although most items are compatible with PA-1400 series, it looks like a few differs:

      • CPU temperature 
        •  {{Preprocessing failed for: {"response":{"@status":"success","result":{"thermal":{"Slot1":{"entry":[
          Unknown macro: {"slot"}

          }

        • 1. Failed: cannot extract value from json by path "$.response.result.thermal.Slot1.entry.DegreesC": no data matches the specified path
      •  Get OSPFv3 neighbor check
        • Preprocessing failed for: <response status="success"><result></result></response>1. Result: {"response":{"@status":"success","result":null}}2. Failed: TypeError: cannot read property 'entry' of null at [anon] (duktape.c:60534) internal at [anon] (function:14) preventsyield
      • Interface [ae1]: Inbound packets discarded, per second
        • {{Preprocessing failed for: {"response":{"@status":"success","result":{"dp":"dp0","hw":
          Unknown macro: {"name"}

          }

        • {{1. Failed: cannot extract value from json by path
          "$.response.result.ifnet.counters.hw.entry.port['rx-discards']": no data matches the specified path}}

      We got a PA-1410, so we would be happy to help test and validate a new template.

            asebiskveradze Aleksandre Sebiskveradze
            MathieuMD Mathieu MD
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Created:
              Updated: