Incident report
-
Resolution: Fixed
-
Major
-
1.8.3
-
None
i've defined this expression on my trigger
{ADSL:ifHCOutOctets.9.time(0)}>081500&
{ADSL:ifHCOutOctets.9.time(0)}<235959
when i test with 070000, i've got true result but true answer is not expected
see the attached image
so i 've made some change to the expression like this:
>81500&
{ADSL:ifHCOutOctets.9.time(0)}<235959
and get the expected result